Measurement is Knowledge


 

Discover a new world of measuring technology with Schneider-Kreuznach. Measurement is knowledge. And if you do not measure, you do not know what you are producing. The optical measurement engineering is subject to extremely high quality demands and standards. With our devices you can guarantee your customer the highest quality assurance.

Schneider-Kreuznach has successfully developed and applied measurement devices in its own production for many years. With our series of premium gauges we can meet even the highest demands to an accuracy of one thousandth of a millimetre. In addition, our gauges feature an operating concept which is unparalleled in the industrial sector in terms of ergonomics and logic.  Some advantages of our measurement devices are:

  • tested and optimized in our own production for many years,
  • a robust design for applications in production,
  • high speed of measurement,
  • high precision of measurement,
  • measurement in accordance with ISO 10110.

VP 30194 CENTER THICKNESS GAUGE FOR LARGE DIAMETER


 

VP 30194 Center thickness gauge for large diamter

The device measures lens center thickness, preferably of previously centered lenses. A central clamp aligns the test pieces centrally to two measuring feelers via their diameter. The feelers are then closed pneumatically and offset against each other in separate digital display electronics. The lens center thickness is displayed immediately. The diameter of the central clamp can be preset, which hugely simplifi es operation when measuring several lenses of the same type.

In order to obtain information quickly about the center thickness of small lenses in the manufacturing process, an extended version of the existing lens center thickness gauge VP 30195 is also available. The device has an integrated laser centering device and can therefore measure even uncentered lenses without any problems.

Testing bench for optics
Testing bench for optics

 

 

 

LENS Ø
15 mm – 150 mm

MEASURING RANGE
60 mm

ACTUATION
manual (hand and foot control)

WEIGHT
approx. 15 kg
(excluding display and control unit)

DIMENSIONS
400 mm × 340 mm × 420 mm (L × W × H)

REQUIRED INFRASTRUCTURE
230 V main voltage and compressed air
low-vibration installation required

VP 30508 CENTERING TESTER


 

Centering tester

The device measures centering errors (surface tilt errors) on individual lenses and on cemented elements in accordance with ISO 10110. The precise and ergonomic V support plate guarantees fi rm support for the lens starting at 5 mm lens diameter.

LENS Ø
5 – 200 mm

RADIUS OF CURVATURE OF THE LENS SURFACES
≥ 5 mm

LENS THICKNESS
Minimum center thickness 0.5 mm, maximum center thickness – limited by clearance between support ring and feeler head

COATED SURFACES
As the refraction of the refl ected beams is measured, given the wave length 635 nm the residual reflection must be > 0.05 %.

ELECTRICAL CONNECTION

  • 230 V, 50 Hz
  • 100 VA via IEC connector
  • DIN 49 457B IEC 320/VI


WEIGHT

  • Mechanical/optical facility: approx. 100 kg
  • Electrical supply and display device: approx. 5 kg
  • Support ring 0.2 – 1.5 kg depending on size


DEVICE COMPONENTS - SENSOR HEAD
The sensor head consists of 2 symmetrical,
identical systems for top and bottom view

 

The system is operated via a Windowsbased analysis computer.

Computer analysis of center testing

 

 

SPECIAL MEASURING SYSTEMS | VP 30370 HDOTF


 

Special optical testing

Our highly specialized measuring systems determine the two-dimensional transfer function (2d MTF) of an object in real time. The test function (the Dirac impulse) is realized using pinholes of different diameters.

The systems can be freely parameterized and allow a semi-automatic measuring method. The resulting parameter data records are managed in a relational database. The same applies to all of the measuring data acquired. An extensive export option, e.g. to Excel, facilitates links to existing QS systems.

A flexible quick release support in a precise and generously dimensioned pivot bearing holds the test pieces. The systems should be kept at a constant temperature (+–2 degrees). For certain measurements, a vibration-free environment is required. The VP 30370 system is mounted on an air-bearing table.

The accuracy of the overall system is calibrated on the basis of special lenses gauged by PTB.

DEVICE COMPONENTS

  • sensor head camera and scan lens
  • target
  • switch cabinet
  • analysis and operating computer

THE MEASURING HEAD
The measuring head consists of several motorized adjustment units of a special CCD camera (cooled) with optimized and specially fine-tuned measuring lenses (highly accurate and gauged), the illumination (stabilized), and exchangeable filter wheels (custom made) adapted to the transfer chain (for quick change of the measuring color).

THE ANALYSIS COMPUTER
The system is operated via a Windowsbased analysis computer. 

Computer analysis

MEASURING RANGE
theoretically up to more than1000 LP/mm,
verifi ed up to 250 LP/mm

OO´

  • infinite
  • finite: min. 1 m and max. 6 m on the optical axis or 3 m with maximum angle of view

MAXIMUM ANGLE OF VIEW
42 degrees


+–50mm

PARAMETERS TO BE MEASURED

  • flange focal distance
  • focal distance
  • MTF via spatial frequency with image
  • height sequence
  • asymmetries
  • field curvature
  • distortion via focal distance variation
  • longitudinal chromatic aberration
  • latitudinal chromatic aberration

WEIGHT
approx. 1500 kg

CONNECTION CONDITION

  • 230V /32 A
  • 6 bar (cleaned, oil-free) air
Measuring head

 

 

Get in Touch

Please do not hesitate to contact us if you have any questions. Our dedicated team is here to help you every step of the way.
Whether you need assistance with product selection, technical specifications, or general inquiries.

Jos. Schneider Optische Werke GmbH
Ringstraße 132
55543 Bad Kreuznach | Germany

Tel: +49 (0) 671 601 205
isales(at)schneiderkreuznach.com
Contact form